Revision history for AmxHardwareDxLink


Revision [257]

Last edited on 2015-10-13 19:37:00 by jmussetter
Additions:
""SubNet""= 255.255.255.0
Deletions:
SubNet= 255.255.255.0


Revision [256]

Edited on 2015-10-13 19:36:27 by jmussetter
Additions:
Goto Switcher Web Console-> Settings: Set ""DxLink"" Ethernet to "Auto" for all ins/outs needed
Deletions:
Goto Switcher Web Console-> Settings: Set "DxLink Ethernet" to "Auto" for all ins/outs needed


Revision [240]

Edited on 2015-10-12 20:58:08 by jmussetter
Additions:
======""DxLink"" Device Family======
//For IP over ""DxLink""://
Deletions:
======Dx Link Device Family======
//For IP over DxLink://


Revision [239]

Edited on 2015-10-12 20:57:42 by jmussetter
Additions:
======Dx Link Device Family======
=====Video and Control over IP=====
//DHCP by default, fallback to static IP://
Push ID button until fast blink (static IP mode)
IP= 192.168.1.2
==Dip Switch Settings:==
//For IP over DxLink://
Set Dips= ||1=ON|2=OFF|3=ON|4=OFF||
Set Dip #3 to ON
//Setup Connection to Master Processor Using TelNet to Device//
Set Device= Device Number
Set Connection= Type TCP + Master's IP
Set IP= IP Address (xxx.xxx.xxx.xxx)
Reboot
===TroubleShooting:===
==Device will not Bind or Stay binded to AMX NI master:==
Goto Switcher Web Console-> Settings: Set "DxLink Ethernet" to "Auto" for all ins/outs needed
Deletions:
======VLinx VESP211======
=====Ethernet Serial Server=====
//Older revisions://
IP= 192.168.0.1
IPPort= 4000
Baud= 9600/N/8/1
//Newer revisions://
IP= 169.254.102.39
IPPort= 4000
Baud= 9600/N/8/1
==Reset Switch Operation:==
0-2 secs= Initiates a Hardware Reset (reboot)
2-10 secs= Enters Console Mode
>10 secs= Resets to Factory Defaults


Revision [238]

The oldest known version of this page was created on 2015-10-12 20:47:44 by jmussetter
Valid XHTML :: Valid CSS: :: Powered by WikkaWiki